Recent Tune-Up projects completed in Westfield, NJ by Infinite Comfort.

Hot Air Furnace repair
Westfield, NJ 07090 · Mar 7, 2026

Hot Air Furnace repair

HeatingRepairTune-UpRepeat CustomerResidential

Client had a problem with the hot air furnace located in the basement. Upon arrival, we found the temperature sensor on the exhaust pipe had triggered. After investigating the exhaust pipe, we found the chimney had some branch accumulation at the bottom, blocking CO2 gases from rising up the chimney and out of the house.
We vacuumed out all the branches, reconnected the pipes, reset the sensor, and now the furnace is working fine. We also did a complimentary carbon monoxide test on a supply vent to make sure the furnace is operating safely, and no signs of a carbon monoxide leak were detected

Read more
central A/C Repair
Westfield, NJ 07090 · Jun 12, 2025

central A/C Repair

Central A/CTune-UpRepeat Customer

The client reported a problem with the first-floor central air-conditioning system, which was not functioning properly. Upon inspecting the outdoor condenser, we found that the wiring connected to the compressor unit had completely melted, causing the capacitor to blow. Additionally, we found that the radiator was extremely dirty, leading the system to operate at very high liquid temperatures.

With the client's permission, we began a deep cleaning of the outdoor condenser. We removed all the condenser covers and power-washed the condenser coil using a commercial degreaser designed to dissolve dirt. Since the unit is a double-wall coil, we power-washed both the outside and the inside coils individually. We also vacuumed all debris from the bottom of the condenser and power-washed it with water to ensure that all the drain ports were clear. We then installed a new run capacitor and replaced the melted wires.

Furthermore, we cleaned the second-floor condenser unit by removing the fan cover, vacuuming all debris inside the unit, and power-washing the bottom of the unit and the internal radiator. We also cleaned the electrical components and checked the capacitors to ensure they were in good condition.

Lastly, we went indoors and cleaned the condensate drain. The client is now ready for summer.

Read more
Central Heating system Repair
Westfield, NJ 07090 · May 23, 2025

Central Heating system Repair

HeatingRepairTune-UpRepeat CustomerResidential

The client reported an issue with the heating system not functioning properly. Upon inspecting the furnace in the basement, I found that the spark ignition cable was disconnected, preventing the heating system from igniting. It appears that another service technician had recently replaced the fan motor and may have forgotten to reconnect the ignition wire after disconnecting the control board.

Additionally, I found a 20 microfarad capacitor simply lying at the bottom of the furnace. If that capacitor were to fall due to the suction from the fan motor, it could potentially surge the entire unit, damaging the control board and possibly causing severe electrical issues. Furthermore, the wiring from the new fan motor was completely loose and could have been sucked into the fan wheel, creating an electrical short.

I reconnected the spark ignition wire to its proper location and turned the system on. The heat started functioning correctly. I also created a bracket for the new capacitor and secured the wiring with zip ties. After testing the system again, it operated properly and was good to go.

Read more
A/C Tune Up
Westfield, NJ 07090 · Jun 20, 2024

A/C Tune Up

Central A/CTune-UpRepeat CustomerResidential

Client had a problem with the HVAC system, not working properly, upon arrival we found the system completely froze up with ice, what’s the ice melt We found a problem with the air filter. Also, the outdoor condenser unit needed to be washed. The coil was extremely dirty.

Read more
Tune Up Central A/C System
Westfield, NJ 07090 · May 24, 2024

Tune Up Central A/C System

Central A/CTune-UpRepeat CustomerResidential

Service the entire HVAC system in two zones, install two traps with sensors, and charge the first floor system with refrigerant

Read more
Service Tune up mini split
Westfield, NJ 07090 · May 13, 2024

Service Tune up mini split

Central A/CTune-UpRepeat CustomerResidential

Service tune-up of the ductless mini-split system.

Read more
Service Hot air furnace and install media Cleaner
Westfield, NJ 07090 · Feb 21, 2024

Service Hot air furnace and install media Cleaner

HeatingTune-UpRepeat CustomerResidential

Deep cleaning of the furnace. Combustion analysis. Wiring adjustment. Electrical components cleaning. Installation of media cleaner and bypass humidifier

Read more
Furnace Tune Up service
Westfield, NJ 07090 · Nov 22, 2023

Furnace Tune Up service

HeatingTune-UpRepeat CustomerResidential

High-efficiency furnace maintenance. Clean burner tubes. Change filters. Clean the condensation drain line. Evaluate combustion. Ensure the furnace is good for winter.

Read more
Hot Air furnace Tune Up
Westfield, NJ 07090 · Nov 17, 2023

Hot Air furnace Tune Up

HeatingTune-UpRepeat CustomerResidential

Furnace maintenance. Cleaning of the furnace. Filter change. Overall inspection of operations.

Read more
Hot Air Furnace Tune Up
Westfield, NJ 07090 · Nov 16, 2023

Hot Air Furnace Tune Up

HeatingTune-UpRepeat CustomerResidential

High-efficiency furnace maintenance. Cleaning of the combustion chamber. Inspection of overall operation of the furnace

Read more
Hot Air Furnace Tune Up
Westfield, NJ 07090 · Nov 6, 2023

Hot Air Furnace Tune Up

HeatingTune-UpRepeat CustomerResidential

Performed hot air furnace maintenance. High-efficiency furnaces. Cleared condensation traps. Cleaned burner tubes with nitrogen. Cleaned electronics with a soft-bristled brush. Tested the gas valve operation.

Read more
Steam Boiler Tune Up
Westfield, NJ 07090 · Oct 18, 2023

Steam Boiler Tune Up

HeatingTune-UpRepeat CustomerResidential

Steam + AC and hot water. Started by having the owner turn on both systems to confirm they were working. Both boilers turned on normally. Shut the systems off using the emergency service switch. Flushed boilers. Cleaned externals and combustion chambers. Applied rust prevention. Turned both systems on and checked radiators.

Read more
Heating Tune Up
Westfield, NJ 07090 · Oct 12, 2023

Heating Tune Up

HeatingTune-UpRepeat CustomerResidential

Performed tune-up. Started the basement furnace. Turned system on from thermostat. System was already set to heat at 70°. Furnace started up normally. Shut system off using emergency service switch. Cleaned flame sensor. Hot surface ignitor glowing bright red and hot. Furnace is working well and ready for winter.

Read more
Central A/C Repair + Tune-Up
Westfield, NJ 07090 · Jun 16, 2023

Central A/C Repair + Tune-Up

Central A/CTune-UpRepeat CustomerResidential

We performed a tune-up for the basement and attic units. We replaced the capacitor for the 2nd-floor unit; the existing one was defective. We checked both units, and everything is working properly.

Read more
Central A/C Tune Up
Westfield, NJ 07090 · Jun 8, 2023

Central A/C Tune Up

Central A/CTune-UpRepeat CustomerResidential

A/C tune-up: Turned systems on from the thermostats. 3 systems total. Went outside to confirm all condensers turned on. All systems working. Removed cover and cleaned inside the condenser. All systems are working well and are ready for summer.

Read more
A/C Tune-Up + Repair
Westfield, NJ 07090 · May 16, 2026

A/C Tune-Up + Repair

Central A/CTune-UpRepeat CustomerResidential

The client called to report a problem with the central air-conditioning system not working.

Upon arrival, we turned the system on and observed the outdoor condenser. The compressor will turn on, but the fan would not.

When we checked the condenser capacitor, we found that the fan side of the capacitor had blown out. Fortunately, it’s beyond repair. A new capacitor is needed. Once we installed the new capacitor, we had a chance to assess the overall functionality of the system and determine that the refrigerant levels are within the proper range.

The unit is achieving an 18° differential; however, the air coming out of the condenser is extremely hot. This is due to the fact that the condenser radiator coil is very dirty internally and needed to be power washed with heavy degreaser.

With the client’s permission, we began servicing the condenser unit. We vacuumed all debris from inside the condenser, power washed the bottom and the coil several times to remove all dirt buildup, then used a brush to clean all electrical components and blew them dry with an air gun.

Inside the house, we discovered that the conversation trap had no access for cleaning. With the client’s permission, we installed a T connection, then found that the trap was clogged. If not addressed, this could lead to a conversation leak.

At this point, everything is ready to go. The system is fully cleaned and operating well.

One-year limited warranty on parts and labor for the capacitor.

Read more