Recent projects completed in Short Hills, NJ by Infinite Comfort.

Central Air-conditioning Repair
Short Hills, NJ 07078 · Sep 25, 2026

Central Air-conditioning Repair

Central A/CRepairRepeat CustomerResidential

Client has a 5-ton Coleman condenser unit that stopped working due to a fan module problem.

Upon arrival, the client turned the system on, and immediately we noticed that the compressor will come on, but the fan will not, we then validate the power is reaching everywhere, confirming the diagnostic that the fan module needed to be replaced.

We picked up a new fan motor and module under warranty from the Coleman distributor, installed the new module, and tested it. We also serviced the condenser unit by vacuuming all the debris inside the condenser, power-washing the condenser coil and condenser floor, blowing all the electrical components with an air gun, then turning the system on . Everything’s working fine.