Recent Central A/C projects completed in Westfield, NJ by Infinite Comfort.

A/C Tune Up
Client had a problem with the HVAC system, not working properly, upon arrival we found the system completely froze up with ice, what’s the ice melt We found a problem with the air filter. Also, the outdoor condenser unit needed to be washed. The coil was extremely dirty.

Tune Up Central A/C System
Service the entire HVAC system in two zones, install two traps with sensors, and charge the first floor system with refrigerant

Service Tune up mini split
Service tune-up of the ductless mini-split system.

Central A/C Repair
AC evaporator coil, line set, and compressor are frozen inside. We proceeded to de-ice the system. We also found that the contactor was not receiving 24 volts. The contactor is defective. Replaced the contactor.

Central A/C Repair + Tune-Up
We performed a tune-up for the basement and attic units. We replaced the capacitor for the 2nd-floor unit; the existing one was defective. We checked both units, and everything is working properly.

Central A/C Tune Up
A/C tune-up: Turned systems on from the thermostats. 3 systems total. Went outside to confirm all condensers turned on. All systems working. Removed cover and cleaned inside the condenser. All systems are working well and are ready for summer.

A/C Repair
The client had a tenant complaining that the central air-conditioning system was not working.
Upon arrival, we turned the system on, and everything activated. We then connected a computer analyzer to the outdoor condenser unit and discovered that the refrigerant charge had leaked out approximately 40%, indicating a scenario of a micro leak.
We inspected some of the piping connections but couldn’t locate any obvious refrigerant leak. In this case, we recommend adding a leak sealant and recharging the remaining refrigerant as needed.
Performed the repair mentioned above also took the opportunity and served the condenser unit for the client. Vacuum all the debris inside power wash the radiator coil clean the electrical components with a air gun.,
Then test the system differential inside the house 21°. Everything is working fine..
Please note that this is an attempt to block the leak and there’s no warranty for this service, but the client has a high success rate due to the amount of refrigerant still in the system.

A/C Tune-Up + Repair
The client called to report a problem with the central air-conditioning system not working.
Upon arrival, we turned the system on and observed the outdoor condenser. The compressor will turn on, but the fan would not.
When we checked the condenser capacitor, we found that the fan side of the capacitor had blown out. Fortunately, it’s beyond repair. A new capacitor is needed. Once we installed the new capacitor, we had a chance to assess the overall functionality of the system and determine that the refrigerant levels are within the proper range.
The unit is achieving an 18° differential; however, the air coming out of the condenser is extremely hot. This is due to the fact that the condenser radiator coil is very dirty internally and needed to be power washed with heavy degreaser.
With the client’s permission, we began servicing the condenser unit. We vacuumed all debris from inside the condenser, power washed the bottom and the coil several times to remove all dirt buildup, then used a brush to clean all electrical components and blew them dry with an air gun.
Inside the house, we discovered that the conversation trap had no access for cleaning. With the client’s permission, we installed a T connection, then found that the trap was clogged. If not addressed, this could lead to a conversation leak.
At this point, everything is ready to go. The system is fully cleaned and operating well.
One-year limited warranty on parts and labor for the capacitor.