Recent Heating projects completed in Westfield, NJ by Infinite Comfort.

Central Heating system Repair
The client reported an issue with the heating system not functioning properly. Upon inspecting the furnace in the basement, I found that the spark ignition cable was disconnected, preventing the heating system from igniting. It appears that another service technician had recently replaced the fan motor and may have forgotten to reconnect the ignition wire after disconnecting the control board.
Additionally, I found a 20 microfarad capacitor simply lying at the bottom of the furnace. If that capacitor were to fall due to the suction from the fan motor, it could potentially surge the entire unit, damaging the control board and possibly causing severe electrical issues. Furthermore, the wiring from the new fan motor was completely loose and could have been sucked into the fan wheel, creating an electrical short.
I reconnected the spark ignition wire to its proper location and turned the system on. The heat started functioning correctly. I also created a bracket for the new capacitor and secured the wiring with zip ties. After testing the system again, it operated properly and was good to go.

Install Ecobee Thermostat
The client wants to install a new Ecobee thermostat for their steam heating system. I connected the thermostat to the boiler, but since this boiler uses a relay to activate the heat, it has caused ground shorting issues, which reset the thermostat.
The only solution is to install a pump controller with an independent power source. This controller will supply power to the thermostat and provide a connection point for the boiler.
I will supply and install the new controller, rewire everything, and ensure that it is tested and working properly. A 1-year limited warranty on parts and labor will be included.

Humidifier Repair
Client would to make sure the humidifier unit is connect tho the hvac system, we look at the wire and water line and its all connected, but we could turn the humidifier system on because the client don’t want to turn the furnace on at this time, in order to activate the humidifier, the heat must be operating. We also noticed that the drain hose was missing,
Connect a new drain hose.

Service Hot air furnace and install media Cleaner
Deep cleaning of the furnace. Combustion analysis. Wiring adjustment. Electrical components cleaning. Installation of media cleaner and bypass humidifier

Thermostat problem
The client had a problem with the Nest thermostat; the previous contractor attempted to install it and blew the furnace fuse. Also, the furnace needs to be deep cleaned, and a medium filter in a humidifier is recommended to be installed

Furnace Tune Up service
High-efficiency furnace maintenance. Clean burner tubes. Change filters. Clean the condensation drain line. Evaluate combustion. Ensure the furnace is good for winter.

Hot Air furnace Tune Up
Furnace maintenance. Cleaning of the furnace. Filter change. Overall inspection of operations.

Hot Air Furnace Tune Up
High-efficiency furnace maintenance. Cleaning of the combustion chamber. Inspection of overall operation of the furnace

Hot Water Heating repair
The client had a problem with the heating system and found a damaged inducer motor and gas valve on a Weil-McLain Ultra boiler.

Hot Air Furnace Tune Up
Performed hot air furnace maintenance. High-efficiency furnaces. Cleared condensation traps. Cleaned burner tubes with nitrogen. Cleaned electronics with a soft-bristled brush. Tested the gas valve operation.

Steam Boiler Tune Up
Steam + AC and hot water. Started by having the owner turn on both systems to confirm they were working. Both boilers turned on normally. Shut the systems off using the emergency service switch. Flushed boilers. Cleaned externals and combustion chambers. Applied rust prevention. Turned both systems on and checked radiators.

Heating Tune Up
Performed tune-up. Started the basement furnace. Turned system on from thermostat. System was already set to heat at 70°. Furnace started up normally. Shut system off using emergency service switch. Cleaned flame sensor. Hot surface ignitor glowing bright red and hot. Furnace is working well and ready for winter.

Replace Hot Air Furnace
Furnace replacement. Coleman 100K SINGLE STAGE 95%