Recent Repair projects completed in Westfield, NJ by Infinite Comfort.

Central Heating system Repair
The client reported an issue with the heating system not functioning properly. Upon inspecting the furnace in the basement, I found that the spark ignition cable was disconnected, preventing the heating system from igniting. It appears that another service technician had recently replaced the fan motor and may have forgotten to reconnect the ignition wire after disconnecting the control board.
Additionally, I found a 20 microfarad capacitor simply lying at the bottom of the furnace. If that capacitor were to fall due to the suction from the fan motor, it could potentially surge the entire unit, damaging the control board and possibly causing severe electrical issues. Furthermore, the wiring from the new fan motor was completely loose and could have been sucked into the fan wheel, creating an electrical short.
I reconnected the spark ignition wire to its proper location and turned the system on. The heat started functioning correctly. I also created a bracket for the new capacitor and secured the wiring with zip ties. After testing the system again, it operated properly and was good to go.

Install Ecobee Thermostat
The client wants to install a new Ecobee thermostat for their steam heating system. I connected the thermostat to the boiler, but since this boiler uses a relay to activate the heat, it has caused ground shorting issues, which reset the thermostat.
The only solution is to install a pump controller with an independent power source. This controller will supply power to the thermostat and provide a connection point for the boiler.
I will supply and install the new controller, rewire everything, and ensure that it is tested and working properly. A 1-year limited warranty on parts and labor will be included.

Kitchen sink leak repair
The client had a leak from the kitchen faucet spray, and the drain connections were held together with electrical tape, which created a high risk of future leaks. The client agreed to replace all drain connections, the kitchen strainer, and the dishwasher tailpiece, and to repair the leak in the spray hose.
We supplied and installed a new P-trap, a new dishwasher tailpiece, a new kitchen strainer, and reconnected everything. After testing for leaks, we found none, and we also fixed the connection on the spray hose.
When running the water, the drain appears to hold a small amount of water before eventually draining away. This observation does not necessarily indicate that the drain is clogged. It seems that there might not be a proper venting connection for this drain.
One-year warranty on parts and labor.

Humidifier Repair
Client would to make sure the humidifier unit is connect tho the hvac system, we look at the wire and water line and its all connected, but we could turn the humidifier system on because the client don’t want to turn the furnace on at this time, in order to activate the humidifier, the heat must be operating. We also noticed that the drain hose was missing,
Connect a new drain hose.

Replace Sump pump
Install a new sump pump with a new check valve, also remove an old water softener system that was not working, and install bypass copper piping

Thermostat problem
The client had a problem with the Nest thermostat; the previous contractor attempted to install it and blew the furnace fuse. Also, the furnace needs to be deep cleaned, and a medium filter in a humidifier is recommended to be installed

Sump Pump Replacement
The Client has a sump pump that needs to be replaced, supply and install a new pump with a new check valve, tested all working fine

Hot Water Heating repair
The client had a problem with the heating system and found a damaged inducer motor and gas valve on a Weil-McLain Ultra boiler.

Central A/C Repair
AC evaporator coil, line set, and compressor are frozen inside. We proceeded to de-ice the system. We also found that the contactor was not receiving 24 volts. The contactor is defective. Replaced the contactor.

Replace Hot Air Furnace
Furnace replacement. Coleman 100K SINGLE STAGE 95%

A/C Repair
The client had a tenant complaining that the central air-conditioning system was not working.
Upon arrival, we turned the system on, and everything activated. We then connected a computer analyzer to the outdoor condenser unit and discovered that the refrigerant charge had leaked out approximately 40%, indicating a scenario of a micro leak.
We inspected some of the piping connections but couldn’t locate any obvious refrigerant leak. In this case, we recommend adding a leak sealant and recharging the remaining refrigerant as needed.
Performed the repair mentioned above also took the opportunity and served the condenser unit for the client. Vacuum all the debris inside power wash the radiator coil clean the electrical components with a air gun.,
Then test the system differential inside the house 21°. Everything is working fine..
Please note that this is an attempt to block the leak and there’s no warranty for this service, but the client has a high success rate due to the amount of refrigerant still in the system.