Recent Central A/C projects completed in Union, NJ by Infinite Comfort.

Service Tune-Up commercial HVAC Volkswagen of Union
The client needs to replace all the air filters on the 5 rooftop units, a total of 20 filters.

Install a new HVAC system
Installed a 100BTU furnace and a 3t 17 seer A/C system

Central A/C Repair
Client had a problem with the central air-conditioning system, not working, found the condensate drain inside the house clogged, and the outdoor condenser needed to be serviced, and the new capacitor replaced

Re-Charge Central A/C System
The client had a problem with the central air-conditioning system not cooling enough. We found that the outdoor condenser had a micro-leak, missing 3 pounds of refrigerant. We added a leak stop and recharged the system. Now everything is working fine

Replace An A/C Condenser
INFINITE COMFORT is pleased to provide the following quotation to install a new 3 Ton Outdoor Condenser Unit
Recovery of any remaining refrigerant from the system
Disconnect the copper line set, electrical wires, and thermostat wires, then remove the old outdoor condenser unit
Supply & install a new Coleman 3-ton outdoor condenser
Supply & install a liquid line filter dryer on the copper line set.
Reconnect all the copper line set, electrical wires, and thermostat wires; test for leaks with nitrogen; vacuum the system for 45 min; then recharge the system with new refrigerant
Also change the drain trap on the coil located in the attic and install a water sensor on the emergency pan.

Installing Ecobee Smart thermostat
The client was experiencing an issue with their Ecobee thermostat, which indicated a power supply problem to the unit. After removing the thermostat from the wall, I measured the voltage on the wire coming into the thermostat and found 14.3V, but it should have read 24 to 28V. At this point, we suspected a potential fuse issue or a malfunctioning transformer.
Next, I moved to the attic space where the unit is located. When I tested the voltage coming into the transformer, I discovered that the unit was receiving 120V, although it should be 220V.
While discussing the situation with the client, we learned that the electrical panel had been recently replaced. I went to the basement to inspect the electrical panel and noticed that the electrician had made a mistake; the air handler unit in the attic is wired to a 120V circuit. There was only one 220V breaker in the panel, which was probably connected to the outdoor condenser unit.
Fortunately for the electrician, since the client has an Ecobee thermostat, the blower motor likely did not burn out due to insufficient power. If it had been a standard digital thermostat, the blower motor could have overheated, damaging the windings. I checked the fan motor, and everything appeared to be in good condition.
The electrician will need to return to trace the circuit wiring and install a 15-amp double-pole breaker for the air handler in the attic.

Central A/C Repair
Client called to report that the central air conditioning system was not working. Upon arrival, we turned on the thermostat, and the system activated; however, it wasn’t producing cold air.
We checked the furnace located in the basement and noticed that the fan was running, but the outdoor condenser wasn’t turning on. When we inspected the outdoor condenser, we discovered that a capacitor had blown. We installed a new capacitor that matched the exact power rating, connected it to the refrigerant lines, and used a computer analyzer to check the system. The analyzer indicated that the condensing unit was operating at extremely high liquid pressure, which suggested a blockage in the condenser coil. Upon further inspection, we confirmed the coil needed cleaning.
With the client’s permission, we installed the new capacitor and began a deep clean of the condenser coil using a power washer and a heavy commercial degreaser specifically made for air conditioning coils. We also serviced the entire condenser unit by vacuuming out all debris from inside, using an air gun to clean all electrical components, and ensuring all wires were tight and secure. We sprayed a silicone coating on all electrical parts and dried them with the air gun. Additionally, we cleaned the condensate drain trap in the basement and vacuumed the pump.
Given the elevated humidity levels inside the house, the client should start feeling the effects of the air conditioning within the next two hours.

Central A/C Repair
The client reported an issue with the first-floor central air conditioning system, which was not functioning properly. Upon arrival, we started the system and inspected the outdoor condenser unit at the back of the house. During our assessment, we discovered that a capacitor had blown. We replaced the damaged capacitor and began tracing the root cause.
After removing the refrigerant cap to connect the refrigerant analyzer, we noticed that the suction line service valve was leaking due to a damaged orifice. Additionally, the analysis revealed that the condenser radiator required a thorough cleaning. The accumulation of dust on the coils caused excessive pressure, which ultimately damaged the capacitor.
With the client’s permission, we thoroughly cleaned the condensing unit. We removed all the covers from the condenser and vacuumed out the debris inside the unit. Then, we power-washed the condenser coil with a commercial degreaser and used an air gun to blow debris out of the electrical components.
Inside the house, we cleaned the floor where debris from the condenser had fallen and vacuumed the second-floor condensation line. After completing our work, we tested both systems, and they are now operating very well.
1-year warranty on capacitor unit

Service Tune Up A/C System
The client would like to tune up the HVAC systems in preparation for the upcoming season.
Begin with the A/C system.
Remove the fan motors to access the bottom of the condenser. Power-wash and vacuum out all debris inside the condenser. Power-wash the condenser coil with water. Brush and blow all electrical parts with an air gun, then spray them with an anti-rust product. Test the capacitor for proper voltage. Clean the condenser cover with soap and water.
Inside the house, brush the condensate drain trap and pour water into the drain to ensure the line is clear. Change the air filter provided by the client.
This concludes the service tune-up for the A/C system

A/C Tune-Up
The client needed service and a tune-up of the central air conditioning system in preparation for the upcoming season.
The client observed that the AC unit wasn’t functioning properly upon inspection, specifically the unit located in the back. We noticed the condensing unit was out of level due to ground erosion, which significantly impacts compressor efficiency.
With the client’s permission, we began servicing the outdoor condenser and corrected the issues.
First, we removed the top condenser fan motor, power-washed and vacuumed the inside of the condenser unit, and power-washed the condenser radiator coil.
In the electrical compartment, we brushed and blew all electrical parts with an air gun. Finally, we cleaned the outdoor condenser cover with soap and water.
Inside the house, we brushed the condensation trap and ran water through the line to ensure it was clear. We checked the air filter, which appears very clean, so no replacement was needed. The system is now ready to go, reaching all the perimeter.

A/C Tune-up
The client wants to tune up the HVAC systems for the upcoming season.
Begin with the A/C system.
Remove the fan motors to access the bottom of the condenser. Power-wash and vacuum out all debris inside the condenser. Power-wash the condenser coil with water. Brush and blow all electrical parts with an air gun, then spray them with an anti-rust product. Test the capacitor for proper voltage. Clean the condenser cover with soap and water.
Inside the house, brush the condensate drain trap and pour water into the drain to ensure the line is clear. Replace the client-provided air filter.
This concludes the service tune-up for the A/C system