Recent Repair projects completed in Union, NJ by Infinite Comfort.

Replace A Steam Boiler
Union, NJ 07083 · Nov 10, 2023

Replace A Steam Boiler

HeatingRepairRepeat CustomerResidential

Steam boiler installation

Read more
Replace A hot water heating circulator pump
Union, NJ 07083 · Dec 7, 2023

Replace A hot water heating circulator pump

HeatingRepairRepeat CustomerResidential

The client has a damaged circulator pump that needs to be replaced so we can re-establish heat in the house

Read more
Commercial Heating Exchanger Replacement
Union, NJ 07083 · Jan 29, 2024

Commercial Heating Exchanger Replacement

HeatingRepairCommercialRepeat Customer

Replace a commercial Heat exchanger on the rooftop unit, the existing exchanger was leaking CO2

Read more
Heating Exchanger Replacement
Union, NJ 07083 · Feb 5, 2024

Heating Exchanger Replacement

HeatingRepairRepeat CustomerResidential

Replaced heat exchanger on hot air  furnace, exchanger under warranty by the manufacturer

Read more
Steam Pipe Replacement
Union, NJ 07083 · Feb 14, 2024

Steam Pipe Replacement

HeatingRepairNew CustomerResidential

Client needs to replace a damaged steam pipe, cut the old pipe off, install a new union connection, and a new pipe, tested all working fine

Read more
Hydro Jetting main sewer line
Union, NJ 07083 · Mar 22, 2024

Hydro Jetting main sewer line

Drain CleaningRepairRepeat CustomerResidential

The client had the main sewer line in the house clogged. After snaking and camera inspection, we found lots of roots in the line. The most efficient way to remove all the roots is with hydro jetting. Water jetting the main sewer line from the house to the street, followed by a camera inspection of the main line, confirmed no roots were left.

Read more
Central A/C Repair
Union, NJ 07083 · May 6, 2024

Central A/C Repair

Central A/CRepairRepeat CustomerResidential

Client had a problem with the central air-conditioning system, not working, found the condensate drain inside the house clogged, and the outdoor condenser needed to be serviced, and the new capacitor replaced

Read more
Re-Charge Central A/C System
Union, NJ 07083 · Jun 24, 2024

Re-Charge Central A/C System

Central A/CRepairRepeat CustomerResidential

The client had a problem with the central air-conditioning system not cooling enough. We found that the outdoor condenser had a micro-leak, missing 3 pounds of refrigerant. We added a leak stop and recharged the system. Now everything is working fine

Read more
Replace An A/C Condenser
Union, NJ 07083 · Aug 1, 2024

Replace An A/C Condenser

Central A/CRepairNew CustomerResidential

INFINITE COMFORT is pleased to provide the following quotation to install a new 3 Ton Outdoor Condenser Unit

Recovery of any remaining refrigerant from the system
Disconnect the copper line set, electrical wires, and thermostat wires, then remove the old outdoor condenser unit
Supply & install a new Coleman 3-ton outdoor condenser
Supply & install a liquid line filter dryer on the copper line set.
Reconnect all the copper line set, electrical wires, and thermostat wires; test for leaks with nitrogen; vacuum the system for 45 min; then recharge the system with new refrigerant
Also change the drain trap on the coil located in the attic and install a water sensor on the emergency pan.

Read more
Installing Ecobee Smart thermostat
Union, NJ 07083 · Mar 13, 2025

Installing Ecobee Smart thermostat

Central A/CRepairRepeat CustomerResidential

The client was experiencing an issue with their Ecobee thermostat, which indicated a power supply problem to the unit. After removing the thermostat from the wall, I measured the voltage on the wire coming into the thermostat and found 14.3V, but it should have read 24 to 28V. At this point, we suspected a potential fuse issue or a malfunctioning transformer.

Next, I moved to the attic space where the unit is located. When I tested the voltage coming into the transformer, I discovered that the unit was receiving 120V, although it should be 220V.

While discussing the situation with the client, we learned that the electrical panel had been recently replaced. I went to the basement to inspect the electrical panel and noticed that the electrician had made a mistake; the air handler unit in the attic is wired to a 120V circuit. There was only one 220V breaker in the panel, which was probably connected to the outdoor condenser unit.

Fortunately for the electrician, since the client has an Ecobee thermostat, the blower motor likely did not burn out due to insufficient power. If it had been a standard digital thermostat, the blower motor could have overheated, damaging the windings. I checked the fan motor, and everything appeared to be in good condition.

The electrician will need to return to trace the circuit wiring and install a 15-amp double-pole breaker for the air handler in the attic.

Read more
Replace Steam Boiler
Union, NJ 07083 · Apr 23, 2025

Replace Steam Boiler

HeatingRepairRepeat CustomerResidential

We replaced an old steam boiler for the client. First, we removed the old boiler and cut all the necessary pipes to prepare the area for the new installation. We then supplied and installed a Crown boiler along with all new piping. The job turned out beautifully.

Read more
Central A/C Repair
Union, NJ 07083 · Jun 7, 2025

Central A/C Repair

Central A/CRepairRepeat CustomerResidential

Client called to report that the central air conditioning system was not working. Upon arrival, we turned on the thermostat, and the system activated; however, it wasn’t producing cold air.

We checked the furnace located in the basement and noticed that the fan was running, but the outdoor condenser wasn’t turning on. When we inspected the outdoor condenser, we discovered that a capacitor had blown. We installed a new capacitor that matched the exact power rating, connected it to the refrigerant lines, and used a computer analyzer to check the system. The analyzer indicated that the condensing unit was operating at extremely high liquid pressure, which suggested a blockage in the condenser coil. Upon further inspection, we confirmed the coil needed cleaning.

With the client’s permission, we installed the new capacitor and began a deep clean of the condenser coil using a power washer and a heavy commercial degreaser specifically made for air conditioning coils. We also serviced the entire condenser unit by vacuuming out all debris from inside, using an air gun to clean all electrical components, and ensuring all wires were tight and secure. We sprayed a silicone coating on all electrical parts and dried them with the air gun. Additionally, we cleaned the condensate drain trap in the basement and vacuumed the pump.

Given the elevated humidity levels inside the house, the client should start feeling the effects of the air conditioning within the next two hours.

Read more
Central A/C Repair
Union, NJ 07083 · Jun 12, 2025

Central A/C Repair

Central A/CRepairRepeat CustomerResidential

The client reported an issue with the first-floor central air conditioning system, which was not functioning properly. Upon arrival, we started the system and inspected the outdoor condenser unit at the back of the house. During our assessment, we discovered that a capacitor had blown. We replaced the damaged capacitor and began tracing the root cause.

After removing the refrigerant cap to connect the refrigerant analyzer, we noticed that the suction line service valve was leaking due to a damaged orifice. Additionally, the analysis revealed that the condenser radiator required a thorough cleaning. The accumulation of dust on the coils caused excessive pressure, which ultimately damaged the capacitor.

With the client’s permission, we thoroughly cleaned the condensing unit. We removed all the covers from the condenser and vacuumed out the debris inside the unit. Then, we power-washed the condenser coil with a commercial degreaser and used an air gun to blow debris out of the electrical components.

Inside the house, we cleaned the floor where debris from the condenser had fallen and vacuumed the second-floor condensation line. After completing our work, we tested both systems, and they are now operating very well.

1-year warranty on capacitor unit

Read more
New Hot Air Furnace Replacement
Union, NJ 07083 · Feb 6, 2026

New Hot Air Furnace Replacement

HeatingRepairRepeat CustomerResidential

During a tune-up visit, we identified a diagnostic issue with the furnace's inducer exhaust system on the first floor; later, after a more detailed diagnosis, we found that the unit was leaking carbon monoxide, and the client decided to replace it rather than repair it.
This also gave us an opportunity to make improvements and install equipment that best fits the ductwork, which was not done properly.

Obtain the required permits from your municipality.

Dismantle and remove the existing supply and return ductwork, gas line, Electrical lines, exhaust lines, and the old furnace.

Supply & install a new Coleman 60.000 BTU furnace with 97% efficiency, dual-stage.
Install a media filter to improve the air quality in the house and help with the static pressure.
This will improve air quality in the house and help with static pressure. Client also has a complaint about the heating in the basement. Unfortunately, the contractor who designed the system installed only one vent, which is not enough. Installed a new 6-inch vent to the basement with a damper so the client can slow it down if needed.
We also noticed there was no supply air in the laundry room, so we added a small register under the box to bring hot air into that room as well.
Reconnect all ductwork, indoor coil, gas line, Electrical lines, and exhaust line

Read more